The numbers a plant engineer asks for
New Era installs the conductive grade. Here is the resistance band it is published at, how that compares with the dissipative grade, and the rest of the cured properties, so you can check the floor against your own ESD program before anybody quotes it.
Conductive
2.5 x 10^4 to 10^6 ohms
Charge drains fastest in this band. Tested to ASTM D257 and ANSI/ESD S7.1.
Dissipative
10^6 to 1.0 x 10^9 ohms
The band most electronics assembly programs specify. Available if yours calls for it.
| Property | Test method | Value |
|---|---|---|
| Resistance, conductive grade | ASTM D257, ANSI/ESD S7.1 | 2.5 x 10^4 to 10^6 ohms |
| Body voltage generation | ANSI/ESD STM 97.2 | 15 V |
| Compressive strength | ASTM D695 | 13,700 psi |
| Flexural strength | ASTM D790 | 9,000 psi |
| Tensile strength | ASTM D638 | 7,800 psi |
| Hardness | ASTM D2240 | 85 Shore D |
| Impact resistance | ASTM D2794 | 120 in-lbs |
| Abrasion resistance | ASTM D4060 | 15 to 20 mg |
| Adhesion over concrete | ASTM D4541 | 400 psi, concrete failure |
| Flame spread, critical flux | ASTM E648 | Class 1 |
| Rate of burning | ASTM D635 | Self-extinguishing |
| Microbial resistance | ASTM G21 | Passes, 0 growth |
| Indoor air quality | CA 01350 | Compliant |
| Moisture vapor permeance | ASTM E96 | 0.08 perms |
| Water absorption | ASTM D570 | Under 0.05 percent |
| Solids content | As supplied | 100 percent |
| Return to foot traffic | At 70F, 50 percent RH | 24 hours |
| Full cure, vehicle traffic | At 70F, 50 percent RH | 7 days |
| Applied thickness | 5 to 7 mil blade | 6 mils typical |
Values are the manufacturer published figures for the conductive system New Era installs. ANSI/ESD S20.20 caps a qualifying floor at under 1 x 10^9 ohms to ground and requires the finished floor to be tested in place, so treat these as the system specification and not as a substitute for your own acceptance test. Call (832) 253-3211 and we will spec it against your program.
What esd flooring is, and why it works in Kingwood
ESD (electrostatic control) flooring controls static so it cannot damage electronics, ignite in sensitive areas, or disrupt processes. The system carries a grounded conductive layer and meets defined resistance ranges for labs, electronics manufacturing and clean spaces, and we test and document the resistance on handover.
ESD Flooring across Kingwood
We install ESD static control flooring throughout Kingwood and the northeast Houston, including these Kingwood areas:
Where static control flooring goes in
If your process can be damaged, degraded or set off by a discharge, this is the floor for it. Tell us what you are protecting and we will spec it to your facility.
Cleanrooms & Labs
Seamless surfaces with integral cove, specified alongside your gowning and airflow protocol.
Warehousing & Distribution
Pick, pack and handling areas moving sensitive product, where the floor is the ground path for everything on it.
Process & Production
Lines running solvents, powders and volatile product, where a spark is a safety problem before it is a quality one.
How a static control floor actually goes down
Five stages. The last one is the one most contractors skip, and it is the only one that proves the floor does what the spec says.
Diamond grind the slab
Mechanical prep to clean, profiled concrete. No acid etch, no bonding to a surface that was never opened up.
Repair and level
Cracks, joints and spalls cut out and filled, moisture tested first and primed if the slab is pushing.
Lay the ground path
The conductive layer and its grounding connections, which is the part that makes it a static control floor instead of a coloured one.
Build the system
Base, conductive media and topcoat to the thickness your spec calls for, phased area by area so the line keeps running.
Test it and hand over readings
Point to point and point to ground measured on the finished floor, in writing. A floor nobody measured is a floor nobody can certify.
Why Kingwood chooses New Era for ESD Flooring
We prep the concrete mechanically, use commercial-grade product, and stand behind it with a written warranty.
- Full diamond-grind surface prep on every Kingwood job, the real reason esd flooring lasts a decade.
- Commercial-grade ESD static control flooring with the right primer, build and topcoat for your space.
- Written one-year workmanship warranty and a 4.9 star rating across 102 reviews.
- Fast-cure options and night or weekend scheduling so your Kingwood home or business keeps moving.
- Established 2015, Houston grown, English and Spanish service end to end.
ESD Flooring in Kingwood FAQ
Twenty-five straight answers for Kingwood, and every one ends with the fastest way to get a quote.
Where a floor has to land
Static control flooring is bought and sold on one number, resistance to ground in ohms. This is that scale. New Era installs in the conductive band, and ANSI/ESD S20.20 will not qualify a floor to the right of the ceiling marked here.
New Era installs in the conductive band, 2.5 x 10^4 to 10^6 ohms.
What makes a floor fail, and how do you prevent it in Kingwood?
Skipped prep and moisture, in that order. That is why the slab gets tested before anything goes down, at 8 to 10 lbs moisture vapor emission (ASTM F1869) and under 80 percent internal relative humidity (ASTM F2170), and why we diamond-grind rather than acid etch. Done right, adhesion pulls 400 psi and the concrete fails before the bond does. The other failure is chemical: the wrong cleaner leaves an insulating film and a floor that passed on handover stops passing. Call (832) 253-3211 for a free Kingwood assessment.
Do you handle the whole ESD static control flooring job in-house in Kingwood?
Yes. One New Era crew handles prep, install and topcoat in Kingwood, no subcontractors passing the buck. It matters more here than on a normal floor, because the electrical performance depends on the base system and the topcoat being installed as one package rather than by two trades. Call (832) 253-3211.
Is ESD flooring worth it for a Kingwood facility?
If your process is static sensitive, the floor is part of the control system rather than a finish. ANSI/ESD S20.20 caps a qualifying floor at under 1 x 10^9 ohms to ground, and a floor outside that band means the rest of your ESD program is carrying the load alone. Specified properly it also takes plant traffic at 13,700 psi compressive and holds its performance instead of losing it in a year. Call (832) 253-3211 for a free Kingwood assessment.
How soon can you start ESD static control flooring in Kingwood?
Book the walkthrough first, because that is where the slab gets tested and the two numbers that decide everything come back: moisture vapor emission (ASTM F1869) and internal relative humidity (ASTM F2170). Often within a week or two after that, depending on the season and the scope. Call (832) 253-3211 and we will lock your Kingwood date.
Do you take small ESD static control flooring jobs in Kingwood?
One kit covers 400 square feet at 6 mils, so a single equipment room is a real job and not a favor. From one room to a full Kingwood plant, we size the crew to the work. Call (832) 253-3211 for a free quote.
Can ESD static control flooring be installed in humid or cold weather in Kingwood?
Yes, and it is governed by numbers rather than the calendar. Material goes down between 50F and 90F, under 90 percent relative humidity, and at least 5F above the dew point. Working time runs 35 minutes at 50F, 25 at 70F and 15 at 90F, and foot traffic returns in 36 hours at 50F against 24 at 70F. On a humid Kingwood day we work to the dew point, which is why the floor cures right instead of blushing. Call (832) 253-3211.
Do you clean up after ESD static control flooring in Kingwood?
Always. We contain the grinding dust with HEPA equipment, protect the surroundings and leave your Kingwood space clean. On a static sensitive process that is not housekeeping, it is part of the job. Call (832) 253-3211.
What primer and topcoat do you use for ESD static control flooring?
A conductive carbon nanotube epoxy topcoat published at 2.5 x 10^4 to 10^6 ohms (ASTM D257, ANSI/ESD S7.1), laid at 5 to 7 mils over a base system matched to your Kingwood slab. It is 100 percent solids and low odor. If the slab tests wet, a moisture mitigation layer goes under it first. Call (832) 253-3211 to discuss.
Will ESD static control flooring add value when selling in Kingwood?
On an industrial building, yes, and for a better reason than appearance. A floor that comes in under 1 x 10^9 ohms to ground is a qualified asset the next owner or tenant can hold to ANSI/ESD S20.20 from day one, rather than a floor they have to tear out before they can run a static sensitive process in your Kingwood building. Call (832) 253-3211 for a free quote.
Do you offer financing for ESD static control flooring in Kingwood?
Ask us about current options. We will give you straight Kingwood pricing and work with your budget. Call (832) 253-3211.
How much does ESD static control flooring cost in Kingwood?
$4 to $14 per square foot covers most Kingwood projects. What moves the number is the resistance grade you have to hit, the condition of the slab and the square footage. We walk the space, measure it and put the price in writing, so call (832) 253-3211 for an exact Kingwood number.
How long does ESD static control flooring take to install in Kingwood?
Two to three days for a single room or bay, prep and cure included. Foot traffic returns about 24 hours after the topcoat at 70F and full cure for forklift traffic is 7 days. Plant wide Kingwood work gets phased area by area so the line never stops. Call (832) 253-3211 and we will scope it against your production schedule.
How long does ESD static control flooring last in Kingwood?
13,700 psi compressive strength and 15 to 20 mg abrasion loss (ASTM D695 and ASTM D4060) is what the cured system is built to, which is why a properly prepped Kingwood floor runs a decade or more under daily traffic. Prep is the variable, not the product. Backed by a written warranty. Get yours quoted at (832) 253-3211.
Do you diamond-grind and prep before ESD static control flooring in Kingwood?
Yes, down to clean profiled concrete before any product goes down, and the Kingwood slab gets tested first. Moisture vapor emission has to come in at 8 to 10 lbs (ASTM F1869) and internal relative humidity under 80 percent (ASTM F2170). Adhesion over properly prepared concrete pulls 400 psi and fails in the concrete rather than at the bond line. Book your Kingwood assessment at (832) 253-3211.
Is ESD static control flooring slip resistant?
Yes. Anti-slip aggregate goes in at 32 oz per batch, tuned to the space so it meets your safety requirement without making the floor hard to clean. The cured texture is round profile, so a microfiber pad lifts particulate instead of dragging it around. Ask about it on your free Kingwood quote at (832) 253-3211.
How do I clean and maintain ESD static control flooring?
A floor handed over at 2.5 x 10^4 to 10^6 ohms can be pushed out of spec by one wrong cleaner. Wax and film forming cleaners leave an insulating layer on top, and that is the most common reason a working static control floor stops passing its own test. Use a cleaner approved for static control floors and nothing else. The surface is seamless, so no grout lines hold dirt, and we leave your Kingwood maintenance crew the written procedure. Call (832) 253-3211.
Do you offer a warranty on ESD static control flooring in Kingwood?
Yes, a written one-year workmanship warranty on every Kingwood install, and we walk the finished floor with you before we call it done. Details at (832) 253-3211.
Can you install ESD static control flooring in Kingwood around our business hours?
Working time is 25 minutes per batch at 70F and foot traffic returns in about 24 hours, so a bay can go down after last shift and be walked on before the next one. We schedule nights and weekends and phase the work area by area so your Kingwood line keeps running. Call (832) 253-3211 to plan it around your shift schedule.
Can you apply ESD static control flooring over an existing floor in Kingwood?
Often yes, and the deciding number is adhesion: over properly prepared concrete this system pulls 400 psi and fails in the concrete, not at the bond line (ASTM D4541). It also bonds to wood, metal and non-glazed tile. A failing coating comes off first, mechanically. We assess the existing Kingwood floor, remove what has to go, repair the slab, then rebuild. We never paint over a bad floor. Book an assessment at (832) 253-3211.
What if my Kingwood slab has moisture problems?
Texas slabs push moisture, so nothing goes down until the Kingwood slab is tested. The limits are 8 to 10 lbs moisture vapor emission (ASTM F1869) and under 80 percent internal relative humidity (ASTM F2170). Over that, a moisture mitigation layer goes in first. Cured, the system runs 0.08 perms and under 0.05 percent water absorption, so it will not bubble or delaminate. Start it right, call (832) 253-3211.
What resistance range does your ESD floor meet?
We install the conductive grade, published at 2.5 x 10^4 to 10^6 ohms (ASTM D257, ANSI/ESD S7.1). The dissipative grade of the same family runs 10^6 to 1.0 x 10^9 ohms if your program specifies that band instead, and ANSI/ESD S20.20 caps a qualifying floor at under 1 x 10^9 ohms to ground either way. We verify the readings before handover. Call (832) 253-3211 for a free Kingwood quote.
Does ESD flooring need grounding?
Yes, and it is what makes the number mean anything: resistance is measured TO GROUND, so a floor with no path to earth has no spec. We install a grounded conductive layer with grounding points so charge drains safely, which is what puts the floor under the 1 x 10^9 ohm ceiling ANSI/ESD S20.20 sets. Call (832) 253-3211 for a free Kingwood quote.
Which standards does it meet?
ANSI/ESD S20.20 is the program standard and ANSI/ESD S7.1 with ASTM D257 is how the floor itself is measured. The system also meets USDA, FDA, EPA and SCAQMD requirements, carries a Class 1 flame spread rating (ASTM E648) and is eligible for LEED points. We document the test results for your records. Call (832) 253-3211 for a free Kingwood quote.
Is it suitable for electronics and labs?
That is exactly what it is specified for: electronics assembly and production, cleanrooms, labs and testing facilities, data server rooms, pharmaceutical and processing areas, battery plants and aircraft hangars. Body voltage generation stays at 15 V under ANSI/ESD STM 97.2, and the cured surface passes ASTM G21 microbial resistance with zero growth. Call (832) 253-3211 for a free Kingwood quote.
Do you test and document the performance?
Yes. We measure resistance across the floor and hand you the documentation on completion. Call (832) 253-3211 for a free Kingwood quote.
More New Era floors in Kingwood
Every system we install in Kingwood, Texas:
ESD Flooring in other Texas cities
Get your ESD floor specified in Kingwood
Free on-site assessment. Tell us the process you are protecting and the resistance range your spec calls for, and we will put the system and the pricing in writing.