The numbers a plant engineer asks for

New Era installs the conductive grade. Here is the resistance band it is published at, how that compares with the dissipative grade, and the rest of the cured properties, so you can check the floor against your own ESD program before anybody quotes it.

What we install

Conductive

2.5 x 10^4 to 10^6 ohms

Charge drains fastest in this band. Tested to ASTM D257 and ANSI/ESD S7.1.

Same family, other grade

Dissipative

10^6 to 1.0 x 10^9 ohms

The band most electronics assembly programs specify. Available if yours calls for it.

Cured system properties, conductive grade
PropertyTest methodValue
Resistance, conductive gradeASTM D257, ANSI/ESD S7.12.5 x 10^4 to 10^6 ohms
Body voltage generationANSI/ESD STM 97.215 V
Compressive strengthASTM D69513,700 psi
Flexural strengthASTM D7909,000 psi
Tensile strengthASTM D6387,800 psi
HardnessASTM D224085 Shore D
Impact resistanceASTM D2794120 in-lbs
Abrasion resistanceASTM D406015 to 20 mg
Adhesion over concreteASTM D4541400 psi, concrete failure
Flame spread, critical fluxASTM E648Class 1
Rate of burningASTM D635Self-extinguishing
Microbial resistanceASTM G21Passes, 0 growth
Indoor air qualityCA 01350Compliant
Moisture vapor permeanceASTM E960.08 perms
Water absorptionASTM D570Under 0.05 percent
Solids contentAs supplied100 percent
Return to foot trafficAt 70F, 50 percent RH24 hours
Full cure, vehicle trafficAt 70F, 50 percent RH7 days
Applied thickness5 to 7 mil blade6 mils typical

Values are the manufacturer published figures for the conductive system New Era installs. ANSI/ESD S20.20 caps a qualifying floor at under 1 x 10^9 ohms to ground and requires the finished floor to be tested in place, so treat these as the system specification and not as a substitute for your own acceptance test. Call (832) 253-3211 and we will spec it against your program.

What esd flooring is, and why it works in Spring

ESD (electrostatic control) flooring controls static so it cannot damage electronics, ignite in sensitive areas, or disrupt processes. The system carries a grounded conductive layer and meets defined resistance ranges for labs, electronics manufacturing and clean spaces, and we test and document the resistance on handover.

ESD Flooring across Spring

We install ESD static control flooring throughout Spring and the north Houston suburbs, including these Spring areas:

Where static control flooring goes in

If your process can be damaged, degraded or set off by a discharge, this is the floor for it. Tell us what you are protecting and we will spec it to your facility.

Cleanrooms & Labs

Seamless surfaces with integral cove, specified alongside your gowning and airflow protocol.

Warehousing & Distribution

Pick, pack and handling areas moving sensitive product, where the floor is the ground path for everything on it.

Process & Production

Lines running solvents, powders and volatile product, where a spark is a safety problem before it is a quality one.

How a static control floor actually goes down

Five stages. The last one is the one most contractors skip, and it is the only one that proves the floor does what the spec says.

01

Diamond grind the slab

Mechanical prep to clean, profiled concrete. No acid etch, no bonding to a surface that was never opened up.

02

Repair and level

Cracks, joints and spalls cut out and filled, moisture tested first and primed if the slab is pushing.

03

Lay the ground path

The conductive layer and its grounding connections, which is the part that makes it a static control floor instead of a coloured one.

04

Build the system

Base, conductive media and topcoat to the thickness your spec calls for, phased area by area so the line keeps running.

05

Test it and hand over readings

Point to point and point to ground measured on the finished floor, in writing. A floor nobody measured is a floor nobody can certify.

Why Spring chooses New Era for ESD Flooring

We prep the concrete mechanically, use commercial-grade product, and stand behind it with a written warranty.

  • Full diamond-grind surface prep on every Spring job, the real reason esd flooring lasts a decade.
  • Commercial-grade ESD static control flooring with the right primer, build and topcoat for your space.
  • Written one-year workmanship warranty and a 4.9 star rating across 102 reviews.
  • Fast-cure options and night or weekend scheduling so your Spring home or business keeps moving.
  • Established 2015, Houston grown, English and Spanish service end to end.

ESD Flooring in Spring FAQ

Twenty-five straight answers for Spring, and every one ends with the fastest way to get a quote.

Where a floor has to land

Static control flooring is bought and sold on one number, resistance to ground in ohms. This is that scale. New Era installs in the conductive band, and ANSI/ESD S20.20 will not qualify a floor to the right of the ceiling marked here.

Resistance scale for static control flooringA logarithmic ohm axis from 10^3 to 10^12. Conductive runs 2.5 x 10^4 to 10^6 ohms and is the band New Era installs. Dissipative runs 10^6 to 1.0 x 10^9 ohms. Above 1 x 10^9 ohms a floor is insulative and does not qualify under ANSI/ESD S20.20.CONDUCTIVEDISSIPATIVEINSULATIVEANSI/ESD S20.20 ceiling, 1 x 109charge drains toward ground103104105106107108109101010111012ohms to ground

New Era installs in the conductive band, 2.5 x 10^4 to 10^6 ohms.

Can you install ESD static control flooring in Spring around our business hours?

Working time is 25 minutes per batch at 70F and foot traffic returns in about 24 hours, so a bay can go down after last shift and be walked on before the next one. We schedule nights and weekends and phase the work area by area so your Spring line keeps running. Call (832) 253-3211 to plan it around your shift schedule.

Can you apply ESD static control flooring over an existing floor in Spring?

Often yes, and the deciding number is adhesion: over properly prepared concrete this system pulls 400 psi and fails in the concrete, not at the bond line (ASTM D4541). It also bonds to wood, metal and non-glazed tile. A failing coating comes off first, mechanically. We assess the existing Spring floor, remove what has to go, repair the slab, then rebuild. We never paint over a bad floor. Book an assessment at (832) 253-3211.

What if my Spring slab has moisture problems?

Texas slabs push moisture, so nothing goes down until the Spring slab is tested. The limits are 8 to 10 lbs moisture vapor emission (ASTM F1869) and under 80 percent internal relative humidity (ASTM F2170). Over that, a moisture mitigation layer goes in first. Cured, the system runs 0.08 perms and under 0.05 percent water absorption, so it will not bubble or delaminate. Start it right, call (832) 253-3211.

Do you repair cracks before ESD static control flooring in Spring?

All of it, before the system goes down, because the topcoat lays at 5 to 7 mils and 6 mils of coating hides nothing. Crack, joint and spall repair is part of Spring prep, not an add-on we discover later. Book your repair and quote at (832) 253-3211.

What colors and finishes can I get with ESD static control flooring in Spring?

Solid colors in a gloss finish. The pigment load is part of the electrical package on a conductive floor, so decorative flake, metallic effects and inlaid logos are not on the table the way they are on a shop floor, and anyone offering them on a static control system is selling you something else. Epoxy ambers under UV, so a Spring space with real daylight gets the UV stable version. Safety striping and zone markings we do add. Call (832) 253-3211.

Is ESD static control flooring good for commercial spaces in Spring?

Industrial, and that is the point of the system: electronics assembly, cleanrooms, labs and testing facilities, battery and electric vehicle plants, aerospace, data server rooms, packaging lines, aircraft hangars, and any Spring area carrying a dust or explosion risk. It is rated for heavy duty forklift and manufacturing traffic at 13,700 psi compressive. Call (832) 253-3211 to plan your project.

How does ESD static control flooring compare to other floor options?

The comparison that matters is resistance, not looks. Conductive runs 2.5 x 10^4 to 10^6 ohms and dissipative runs 10^6 to 1.0 x 10^9 ohms, and ANSI/ESD S20.20 caps a qualifying floor at under 1 x 10^9 ohms to ground. Below that band you are draining charge faster; above it you are outside the standard. Which one you need is set by your own ESD program, and we will walk you through it at no cost. Call (832) 253-3211.

Will ESD flooring in Spring handle forklifts, pallet jacks and heavy point loads?

13,700 psi compressive, 9,000 psi flexural, 120 in-lbs impact and 85 Shore D hardness (ASTM D695, D790, D2794 and D2240). It is specified for heavy duty forklift and manufacturing areas. Full cure before vehicle traffic is 7 days. Free Spring quote at (832) 253-3211.

When can I use the floor after ESD static control flooring in Spring?

About 24 hours to foot traffic at 70F, 36 hours if the space is running cold at 50F, and 7 days to full cure for vehicles and forklifts. Working time per batch is 25 minutes at 70F, which is what sets how the crew stages the area. We give you the exact Spring schedule. Call (832) 253-3211.

What kind of facilities need ESD flooring in Spring?

Anywhere an uncontrolled discharge costs you a part or a person: electronics assembly, cleanrooms, labs and testing facilities, battery and electric vehicle plants, aerospace and defense, data server rooms, packaging lines, 911 call centers, aircraft hangars, and any Spring process carrying a dust or explosion risk. If your ESD program cites ANSI/ESD S20.20, the floor has to come in under 1 x 10^9 ohms to ground and be tested in place to prove it. Call (832) 253-3211 and tell us what you are protecting.

Is ESD static control flooring chemical and stain resistant?

Rated in the best category against motor oil, jet fuel, premium gasoline, brake fluid, hydraulic fluid, 30 percent ammonia, 50 percent caustic soda, 20 percent sodium chloride and hard well water. Some solvents are not recommended, and we will say so rather than find out on your floor: acetone, MEK, methanol, ethanol and 37 percent battery acid among them. Tell us what gets spilled in your Spring space and you get a straight answer. Call (832) 253-3211.

Hablan Espanol en Spring?

Si. Cotizamos y trabajamos en ingles o espanol en Spring. Llame al (832) 592-3808, o al (832) 253-3211 para una cotizacion gratis.

Do you offer free estimates in Spring?

Always, and it includes the two slab tests that decide the whole system: moisture vapor emission (ASTM F1869) and internal relative humidity (ASTM F2170), plus an assessment of whatever is already down. We measure, talk through the options and put the pricing in writing at no cost. Call (832) 253-3211 and we typically respond within 24 hours.

Can you add anti-slip or safety features to ESD static control flooring?

Yes. Anti-slip aggregate blends in at 32 oz per kit, and we add safety striping, zone markings and high visibility lines wherever the Spring plant needs them. Call (832) 253-3211.

Can you handle large Spring jobs and multi-phase work?

One kit covers 400 square feet at 6 mils, so a plant wide Spring job is a scheduling problem rather than a capability one. We phase it area by area so your operation never stops. Call (832) 253-3211 to plan it.

What system do you use for ESD static control flooring?

A conductive carbon nanotube epoxy topcoat, published at 2.5 x 10^4 to 10^6 ohms (ASTM D257, ANSI/ESD S7.1). It is 100 percent solids and low odor, and it lays over a prepared base system at 5 to 7 mils. The dissipative grade of the same family runs 10^6 to 1.0 x 10^9 ohms if your program calls for that band instead. Decorative flake, metallic and polished concrete are not static control systems and we will not sell them to you as one. Call (832) 253-3211.

What Spring areas do you serve?

Fourteen service areas across the Houston, Austin and San Antonio metros, Spring included, plus the surrounding Texas markets. Call (832) 253-3211 and we will confirm we cover your address and book a free estimate.

Why choose New Era for ESD static control flooring in Spring?

Because the floor gets a number instead of an adjective. Full diamond-grind prep, a conductive system published at 2.5 x 10^4 to 10^6 ohms (ASTM D257, ANSI/ESD S7.1), and one crew from the grind to the topcoat on every Spring job. 4.9 stars across 102 reviews. Free quote at (832) 253-3211.

What is the process for ESD static control flooring in Spring?

Test, grind, repair, prime, build, topcoat. The slab gets tested first (ASTM F1869 and ASTM F2170), then we diamond-grind to clean profiled concrete, repair cracks and joints, prime where the slab needs it, then lay the conductive topcoat at 5 to 7 mils. Foot traffic at 24 hours, full cure at 7 days. You get the Spring schedule up front. Call (832) 253-3211.

Can I see examples of ESD static control flooring you have done near Spring?

Yes. We will share recent Spring-area photos and references so you can see the finish before you commit. Call (832) 253-3211.

What resistance range does your ESD floor meet?

We install the conductive grade, published at 2.5 x 10^4 to 10^6 ohms (ASTM D257, ANSI/ESD S7.1). The dissipative grade of the same family runs 10^6 to 1.0 x 10^9 ohms if your program specifies that band instead, and ANSI/ESD S20.20 caps a qualifying floor at under 1 x 10^9 ohms to ground either way. We verify the readings before handover. Call (832) 253-3211 for a free Spring quote.

Does ESD flooring need grounding?

Yes, and it is what makes the number mean anything: resistance is measured TO GROUND, so a floor with no path to earth has no spec. We install a grounded conductive layer with grounding points so charge drains safely, which is what puts the floor under the 1 x 10^9 ohm ceiling ANSI/ESD S20.20 sets. Call (832) 253-3211 for a free Spring quote.

Which standards does it meet?

ANSI/ESD S20.20 is the program standard and ANSI/ESD S7.1 with ASTM D257 is how the floor itself is measured. The system also meets USDA, FDA, EPA and SCAQMD requirements, carries a Class 1 flame spread rating (ASTM E648) and is eligible for LEED points. We document the test results for your records. Call (832) 253-3211 for a free Spring quote.

Is it suitable for electronics and labs?

That is exactly what it is specified for: electronics assembly and production, cleanrooms, labs and testing facilities, data server rooms, pharmaceutical and processing areas, battery plants and aircraft hangars. Body voltage generation stays at 15 V under ANSI/ESD STM 97.2, and the cured surface passes ASTM G21 microbial resistance with zero growth. Call (832) 253-3211 for a free Spring quote.

Do you test and document the performance?

Yes. We measure resistance across the floor and hand you the documentation on completion. Call (832) 253-3211 for a free Spring quote.

Get your ESD floor specified in Spring

Free on-site assessment. Tell us the process you are protecting and the resistance range your spec calls for, and we will put the system and the pricing in writing.

Get your free quote

Tell us about your space. We reply fast, in English or Español.

No spam. Your details go straight to the New Era crew.

Powered by WebKing.com WebKing Your Partner in Digital Marketing Services